Intra- and inter-session reliability of the MyotonPro in measuring the biomechanical and viscoelastic properties of the knee extensor and flexor muscles

dc.authorid0000-0002-4476-3785
dc.authorid0000-0003-4355-3134
dc.authorid0000-0002-6899-852X
dc.contributor.authorSeçer, Erhan
dc.contributor.authorBayram, Kazım
dc.contributor.authorKaya Özer, Derya
dc.date.accessioned2026-07-27T06:42:29Z
dc.date.available2026-07-27T06:42:29Z
dc.date.issued14 May 2026
dc.departmentDiğer
dc.departmentKapadokya Üniversitesi, Sağlık Bilimleri Yüksekokulu, Fizyoterapi ve Rehabilitasyon Bölümü
dc.departmentDiğer
dc.description.abstractBackground The MyotonPro is a widely used, safe, and non-invasive digital device for assessing muscle biomechanical and viscoelastic properties. This study aimed to determine the intra- and inter-session reliability of the MyotonPro in measuring the biomechanical and viscoelastic properties of the knee extensor and flexor muscles. Methods Eighty-four young male recreational athletes, with a mean age of 21.42 ± 1.37 years, participated in a fourstage repeated-measure study. Both sessions followed the same protocol: rectus femoris (RF) and biceps femoris (BF) measurements were taken twice per side and averaged, with a 30-min interval between sets. Two different intraclass correlation coefficient (ICC) models were used: ICC3,1 (two-way mixed effects, absolute agreement) for intra-session reliability and ICC2,1 (two-way random effects, absolute agreement) for inter-session reliability. Standard error of measurement (SEM) was calculated using SEM = SDpooled x √(1-ICC). The minimal detectable change (MDC95) was calculated using the formula MDC95 = 1.96 × √2 × SEM. Bland–Altman plots were generated to visually represent the agreement between the two sessions, complementing the ICC analysis. Results The MyotonPro demonstrated high to excellent intra-session reliability across all measured properties (tone, stiffness, elasticity, relaxation time, and creep) for both the RF (ICCs ≥ .95, ranging from .95 to .99; SEM: 0.01 to 6.14; MDC95: 0.04 to 17.03) and the BF (ICCs ≥ .97, ranging from .97 to .99; SEM: 0.02 to 5.27; MDC95: 0.05 to 14.62). The MyotonPro demonstrated excellent inter-session reliability across all measured properties for both the RF (ICCs ≥ .96, ranging from .96 to .99; SEM: 0.02 to 4.38; MDC95: 0.05 to 12.14) and the BF (ICCs ≥ .94, ranging from .94 to .99; SEM: 0.02 to 5.17; MDC95: 0.07 to 14.54). The Bland–Altman analysis confirmed near agreement for all measured properties across sessions 1 and 2 for both the RF and BF. The limits of agreement encompassed most data points, and the overall systematic mean bias was negligible, remaining close to zero. Conclusions This study establishes the MyotonPro as a highly reliable instrument for assessing muscle properties, evidenced by excellent intra-session and inter-session consistency across all measured biomechanical and viscoelastic properties. The negligible systematic bias indicates high temporal measurement stability, supporting the potential utility of myotonometry for monitoring changes in muscle mechanical properties in longitudinal assessments.
dc.identifier.urihttps://hdl.handle.net/20.500.12695/4279
dc.institutionauthorBayram, Kazım
dc.institutionauthorid0000-0003-4355-3134
dc.language.isoen
dc.relation.publicationcategoryMakale - Uluslararası - Editör Denetimli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHamstring muscle
dc.subjectQuadriceps muscle
dc.subjectMuscle tone
dc.subjectReliability
dc.subjectStiffness
dc.subjectElasticity
dc.titleIntra- and inter-session reliability of the MyotonPro in measuring the biomechanical and viscoelastic properties of the knee extensor and flexor muscles
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Intra- and inter-session reliability.pdf
Boyut:
3.14 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: