Effects of nocturnal complete denture usage on cardiorespiratory parameters: A pilot study

dc.contributor.authorUyar, Alper
dc.contributor.authorPişkin, Bülent
dc.contributor.authorŞenel, Buğra
dc.contributor.authorAvsever, Hakan
dc.contributor.authorKarakoç, Ömer
dc.contributor.authorTaşçı, Cantürk
dc.date.accessioned2022-03-22T09:49:08Z
dc.date.available2022-03-22T09:49:08Z
dc.date.issued2021en_US
dc.departmentKapadokya Üniversitesi, Uygulamalı Bilimler Yüksekokulu, Havacılık Elektrik ve Elektroniği Bölümü
dc.descriptionTARAMAPUBMED
dc.descriptionTARAMASCOPUS
dc.description.abstractStatement of problem: Sleeping without conventional complete dentures (CCDs) has been stated by some to induce negative effects on the cardiorespiratory functions of edentulous patients with obstructive sleep apnea (OSA), although others have reported the exact opposite. Therefore, a consensus on nocturnal CCD usage is lacking. Purpose: The purpose of this clinical study was to assess the effects of nocturnal denture usage on cardiorespiratory stability by using pulse oximetry (PO). Materials and methods: Thirty CCD wearers were enrolled in the study. The first nocturnal pulse oximetry (FNPO) recordings were made on 3 different nights while the participants were sleeping without dentures (WOD). Oxygen desaturation index (ODI) and other PO parameters of the participants, including total respiratory event (TRE), basal SpO2 (BSpO2), time?88 (T88), average low SpO2 (ALSpO2), total pulse event (TPE), average pulse rate (APR), and heart rate variability index (HRVI), were processed and the obtained data were recorded as WOD condition values. According to the ODI scores, the OSA status of the participants was grouped as normal (ODI<5), mild (5<ODI<15), moderate (15<ODI<30), or severe (ODI>30). Complete dentures were fabricated by an experienced prosthodontist and a dental laboratory technician by following conventional procedures. At the end of the first month of the follow-up period, the second nocturnal PO recordings (SNPO) were made on 3 different nights while the participants slept wearing dentures (WID), and the data obtained were recorded as WID condition values. The comparison of mean PO values obtained from WOD and WID were analyzed with the Wilcoxon signed- rank test (?=.05). Results: Significant differences were found between WOD and WID values in terms of TRE (P=.01), ODI (P=.001), ALSpO2 (P=.006), TPE (P=.001), and HRVI (P=.001) parameters. The significance of the improvements in the WID condition increased with the severity of OSA. Conclusions: Improvements were observed in substantial cardiorespiratory parameters such as the ODI and HRVI of the participants wearing dentures nocturnally.
dc.identifier.doi10.1016/j.prosdent.2021.01.008
dc.identifier.scopusqualityN/A
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2021.01.008
dc.identifier.urihttps://hdl.handle.net/20.500.12695/1557
dc.identifier.volume21en_US
dc.identifier.wosWOS:000892488100019
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Sceince
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorPişkin, Bülent
dc.language.isoen
dc.publisherElseiver
dc.relation.ispartofThe Journal Of Prosthetic Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[Keywords Not Available]
dc.titleEffects of nocturnal complete denture usage on cardiorespiratory parameters: A pilot study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
1-s2.0-S0022391321000457-main.pdf
Boyut:
241.63 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale / Article
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: